Home | Terms of Business | Delivery Rates  
  M & M Controls

Tel: +44 (0)1772 699 999

Fax: 0844 292 7678 sales@mandmcontrols.com

 
 
 
Home About Us Quote Online Customer Service Contact Us Buy Online
 
Product Lines
  1. ATI BTI MTI SDT Timers
  2. AV210 Angle-seat valve
  3. AVTA Thermostatic valve
  4. AVTB Thermostatic valve
  5. BCP Pressure controller
  6. CAS Pressure switch
  7. CAS Temperature switch
  8. CI 6 9 12 16 25 50 Contactor
  9. CS Pressure Switch
  10. CTI Circuit breakers
  11. EMP 2 Transmitter
  12. ETB Clip-on timer
  13. EV210A Direct-operated solenoid valve
  14. EV210B Direct operated solenoid valve
  15. EV215B Direct-operated solenoid valve
  16. EV220A with filter Servo-operated solenoid valve
  17. EV220A Servo-operated solenoid valve
  18. EV220B 15-50 Servo-operated solenoid valve
  19. EV220B 6-22 Direct-operated solenoid valve
  20. EV220B 65-100 Servo-operated solenoid valve
  21. EV220X Externally operated valve
  22. EV222B Servo-operated solenoid valve
  23. EV224B Servo-operated solenoid valve
  24. EV225B Servo-operated solenoid valve
  25. EV250B Assisted-lift solenoid valve
  26. EV260B Proportional valve
  27. EV310A Direct-operated 3 way solenoid valve
  28. EV310B Direct-operated 3 way solenoid valve
  29. FJVA Thermostatic valve
  30. KP - KPI Pressure Switch
  31. KP - KPI Thermostat
  32. KPS Pressure Switch
  33. KPS Temperature Switch
  34. MBC 5000 Pressure switch
  35. MBC 5100 Pressure switch
  36. MBC 5180 Pressure switch
  37. MBD 1000 Plug-in display
  38. MBS 1700/1750 Transmitter
  39. MBS 3000 Transmitter
  40. MBS 3050 Transmitter
  41. MBS 32 Transmitter
  42. MBS 3250 Transmitter
  43. MBS 33 Transmitter
  44. MBS 33M Transmitter
  45. MBS 4010 Transmitter
  46. MBS 4510 Transmitter
  47. MBS 4701 Transmitter
  48. MBS 5100 Transmitter
  49. MBS 5150 Transmitter
  50. MBT 153 Sensor
  51. MBT 3260 Sensor
  52. MBT 3560 Sensor
  53. MBT 5252 Sensor
  54. MBV 2000 Isolation valve
  55. MBV 3000 Test valve
  56. MBV 5000 Test valves
  57. MCI TCI Soft starters
  58. RT Pressure switch
  59. RT Thermostat
  60. TI 9 16 30 80 86 Thermal overload
  61. WVTS Thermostatic valves
 

Danfoss Contactors


Danfoss contactors CI ranges CI4, CI5, CI6, CI9, CI12, CI15, CI16, CI20, CI25, CI30 and CI61 up to CIEI420 which includes mini contactors from 2.2. to 4 kW and control relays/ contactors from 2.2 to 238 kW.
The range of auxiliary functions and accessories is very comprehensive and includes: auxiliary contact blocks, timer blocks, interface modules, suppression blocks, mechanical interlocks, rating plates and many more.

 
Danfoss Contactor  - Now *** OBSOLETE - REPLACED BY CI 5 *** For reference only!
Danfoss Contactor - Now *** OBSOLETE - REPLACED BY CI 5 *** For reference only! - CI 4 037H3212, 037H3213, 037H3143, 037H3144, 037H314, 037H3146, 037H3147, 037H3459, 037H3460
The Danfoss mini contactor is a small, compact unit, typically with 3 NO main contacts and a built-in normally open (NO) or normally closed (NC) auxiliary contact. Operation, overload protection and phase failure protection of induction motors are typical applications for the mini contactor, combined with a thermal overload relay.
Compact design
Screw or DIN rail mounting
Power range 1.5 to 5.9 kW
Basic module with one built-in aux. contact (NO or NC)
For ac and dc coil voltages
Low-power dc coils suitable for PC and PLC control
Data Sheet CI 4 pdf
Conversion Chart CI4 to CI5

Danfoss Contactor
Danfoss Contactor - CI 5 037H3500, 037H3501, 037H3502, 037H3503, 037H3504, 037H3505, 037H3506, 037H3507, 037H3508
Danfoss CI 5- mini contactors cover the power range up to 5.5 kW and are available for AC and DC coil voltages enabling reliable working with extremely low and high voltage fluctuations.
Characteristic of the minicontactors is that they are compact and suitable for applications where space is at a premium. With add-on auxiliary contact blocks, timers and other additional accessories they off er high flexibility.
The CI 5- also guarantees extra safety against electric shock by protective distance for live parts during mounting by installers and maintenance stuff according to IEC 60947 edition 5 standard.
The CI 5- also includes dedicated bimetallic overload protection relays for sensitive to phase-loss condition.
In addition, the CI 5- range also includes thermal overload relays for the protection of squirrel-cage motors.
Compact design
High flexibility
Power range up to 5.5 kw
For ac and dc coil voltages 
Data Sheet CI 5 pdf
Buy Online Now!

Danfoss Contactor
Danfoss Contactor - CI 6-50 037H001531, 037H001831, 037H002113, 037H002116, 037H002131, 037H002132, 037H002137, 037H002231, 037H003116, 037H003131, 037H003132, 037H003137, 037H003231, 037H004131, 037H004137, 037H004531, 037H004931, 037H005031, 037H005116, 037H005132, 037H005137, 037H005532, 037H005631,
The Danfoss contactor programme CI 6-50 is based on three frame sizes. The smallest frame size consists of CI 6-15 (2.2-7.5 kW), the middle contains the CI 16-30 range (7.5-15 kW) and the largest frame size is represented by the CI 32-50 (15-25 kW). All frame sizes are provided with three NO main contacts. CI 6-15 are available with four NO main contacts. 
Compact design in three frame sizes
Screw or DIN rail mounting
Power range 2.2 to 25 kW
For ac/dc coil voltages 
Data Sheet CI 6-50 pdf
Buy Online Now!

Danfoss Contactor
Danfoss Contactor - CI 61-86 037H3061, 037H3062, 037H3063
The Danfoss contactor programme CI 61-86 consists of one frame size with three NO main contacts. Coils are standard for dual frequency. A long electrical lifetime makes the CI 61-86 contactors suitable for operation of all kinds of electrical loads in modern industry. Combined with a thermal overload relay, the contactor switches and protects induction motors against overload and asymmetric load. A wide range of clip-on aux. contacts, timers, surge suppressors, mechanical interlock and marking plates makes the CI 61-86 programme very flexible and suitable both for OEMs and panel builders.
Compact design
Screw or DIN rail mounting
Power range 30 kW to 45 kW
For ac coil voltages  
Data Sheet CI 61-86 pdf
Buy Online Now!

Danfoss Contactor
Danfoss Contactor - CI 110-180
The Danfoss contactor programme CI 110-180 consists of one frame size with three NO main contacts and one auxiliary contact block with one NO and one NC auxiliary contact. Spare contacts are available and by maintenance, the moveable system blocks when removing the chamber. By replacing contacts, wire separation from terminals is not necessary. A long electrical lifetime makes the CI 110-180 contactors suitable for operation of all kinds of electrical loads in modern industry. Combined with a thermal overload relay or an electronic motor protection relay, the contactor switches and protects induction motors against overload and asymmetric load. A wide range of clip-on aux. contacts, timers, surge suppressors, mechanical interlock and marking plates makes the CI 110-180 programme very flexible and suitable both for OEMs and panel builders.
Compact design
Screw mounting
Power range 55 kW to 90 kW
Basic modules with aux. contacts (1 NO + 1 NC)
For ac coil voltages 
Danfoss CI 110-180 pdf
Buy Online Now!

Danfoss Contactor
Danfoss Contactor - CI EI 9-30
The Danfoss contactor programme CI 9 EI - 30 EI is based on two frame sizes. The small frame size consists of the CI 9 EI - 15 EI (4-7.5 kW), and the CI 25 EI - 30 EI range (11-15 kW) uses the large frame size. Both are equipped with three NO main contacts. Applications include all kinds of 24 V dc output PLC controlled systems. A long electrical lifetime makes the CI 9 EI - 30 EI contactors suitable for operation of all kinds of electrical loads in modern industry. Combined with a thermal overload relay or an electronic motor protection relay, the contactor switches and protects induction motors against overload and asymmetric load. A wide range of clip-on aux. contacts, timers, surge suppressors, mechanical interlock and marking plates makes the CI 9 EI 30 EI programme very flexible and suitable both for OEMs and panel builders. 
Compact design
Screw or DIN rail mounting
Power range 4 kW to 15 kW
Electronic control of switching coil voltage
Integrated interface relay for PLC application  
Data Sheet CI EI 9-30 pdf

Danfoss Contactor
Danfoss Contactor - CI EI 170-420
The Danfoss contactor programme CI 210 EI - 420 EI consist of one frame size. The series are equipped with three NO main contacts and an auxiliary contact block with one NO and one NC auxiliary contact. Spare contacts are available and by maintenance, the moveable system blocks when removing the chamber. The factory setting makes the contactors operate as standard conventional contactors, but for PLC application, the built-in interface relay can be activated. A long electrical lifetime makes the CI 210 EI - 420 EI contactors suitable for operation of all kinds of electrical loads in modern industry. A wide range of clip-on aux. contacts, timers, surge suppressors, mechanical interlock and marking plates makes the CI 210 EI - 420 EI programme very flexible and suitable both for OEMs and panel builders. 
Compact design
Screw mounting
Power range 110 kW to 220 kW
Basic modules with built-in aux. contacts
Electronic control of switching coil voltage
Wide voltage range
Dual frequency coil at 50-60 Hz as standard
Integrated interface relay for PLC application 
Data Sheet CI EI 170-420 pdf
Buy Online Now!
     
 
  Home | About Us | Sitemap | Contact Us  
       
  M&M Controls Unit 17 & 18, Roundhouse Court Barnes Wallis Way, Buckshaw Village, Chorley Lancashire - UK PR7 7JN
Tel: +44 (0)1772 699 999 Fax: 0844 292 7678 sales@mandmcontrols.com Email: info@mandmcontrols.co.uk
Copyright M & M Controls 2013. All rights reserved  
       
  . . . . . .
 
M&M Controls Buy Online