Danfoss Overload Relays
The Danfoss thermal overload relay range TI9 C, TI16 C, TI25 C, TI30 C, TI80 & TI86 are used with the contactor range CI 4 - CI 86 to give protection of squirrel-cage motors. The Danfoss electronic motor protection relays TI 180E and TI 630E give effective protection of electric motors exposed to thermal overload, phase failure and asymmetrical load. The selection of a Danfoss thermal overload relay must be based on the motor full load current and the method of starting: - With direct start range for motor starter is used. - With star – delta start the range for Y/D starter is used.
|
|
|
Danfoss Overload Relay - TI 9C-5 047H3130 047H3131 047H3132 047H3133 047H3134 047H3135 047H3136 047H3137 047H3138 047H3139 047H3140 |
The Danfoss thermal overload relay TI 9C-5 is used with minicontactor CI 5 – for protection of squirrel cage motors where compactness is required. The relay have single – phase protection, i.e. accelerated release if phase drop-out occurs. This is particularly important for motors with delta connected windings. Stop reset button Stop/reset button Manual/automatic reset Test button Double scale for direct start or Y/Δ start Galvanically isolated signal contact |
Data Sheet TI9C-5 pdf
|
Buy Online Now!
|
|
|
Danfoss Overload Relay - TI 16 C - 30 C 047H0200, 047H0201, 047H0202, 047H0203, 047H0204, 047H0205, 047H0206, 047H0207, 047H0208, 047H0209, 047H0210, 047H0211, 047H0212, 047H0213, 047H0214, 047H0215, |
The thermal overload relays TI 16C-30C cover the range from 0.13-32 Amp and protect squirrel cage motors of up to 15 kW against overload. The phase failure function accelerates the trip function by three phase run if a phase drop-out occurs. This is particularly important for delta connected motors. For use with contactors CI 6 - CI 30 Compact design Stop/reset button Manual/automatic reset function Test trip function DOL scale / Y-Δ scale Galvanically isolated signal contacts Single phase failure protection |
Data Sheet TI16 C - 30 C pdf
|
Buy Online Now!
|
|
|
Danfoss Overload Relay - TI 80-86 |
The thermal overload relays TI 80-86 cover the range from 16-85 Amp and protect squirrel cage motors of up to 45 kW against overload. For use with contactors CI 32 to CI 86 Compact design Stop/reset button Manual/automatic reset function Test trip function DOL scale / Y-Δ scale Changeover contact Single phase failure protection |
Data Sheet TI 80-86
|
Buy Online Now!
|
|
|
Danfoss Overload Relay - TI C 9-12 |
The Danfoss thermal overload relays TI 9 C cover the range from 0.13 - 9.2 Amp. The phase failure function accelerates the trip function by three phase run if a phase drop-out occurs. This is particularly important for delta connected motors. For use with mini contactors CI 4 Compact design Stop/reset button Manual/automatic reset function Test trip function Double scale for direct start or Y-∆ start Galvanically isolated signal contacts Single phase failure protection |
Data Sheet TI C 9-12 pdf
|
Buy Online Now!
|
|
|
Danfoss Overload Relay - TI 180 E |
The Danfoss electronic motor protection relay covers the range from 20-180 Amp and protects squirrel cage motors of up to 95 kW against overload. The trip curve is adjustable from 2-30s in able to fit the actual application. LED status indication for availability of control supply LED status indication for thermal overload trip LED status indication for single phase failure LED status indication for high motor winding temperature Remote stop option Status indication and reset function from panel door option Adjustable trip setting curve Reset button Manual reset function Test trip function DOL scale Galvanically isolated contacts |
Data Sheet TI 180 E pdf
|
|
|
|
Danfoss Overload Relay - TI 630 E |
The Danfoss electronic motor protection relay covers the range from 160-630 Amp and protects squirrel cage motors of up to 238 kW against overload. The trip curve is adjustable from 2-30s in able to fit the actual application. LED status indication for availability of control supply LED status indication for thermal overload trip LED status indication for single phase failure LED status indication for high motor winding temperature Remote stop option Status indication and reset function from panel door option Adjustable trip setting curve Reset button Manual reset function Test trip function DOL scale Galvanically isolated contacts |
Data Sheet TI 630 E pdf
|
|
|
|